Electronic Shutdown And Logic System
Electronic Shutdown And Logic System
Tanggal
27 February – 01 March 2012
09-12 May 2012
09-12 Juni 2012
03-06 December 2012
Pukul
09.00-17.00 WIB
Tempat
Hotel Grand Seriti Boutique Bandung
INTRODUCTION AND GOAL :
This training is meant to improve knowledge and horizons on electronic shutdown and logic system. The training will emphasize on PLC use in handling shutdown system. How to develop logic system on shutdown system will be explained and covered others such as failure and reliability, SIS, BPCS, SDSS, DAS, PLC elaboration on hardware, software and implementation, hazardous area and electrical classification. After training completed, participants are hoped to have comprehension understanding on electronic shutdown and logic system and how these all are implemented.
TRAINING MATERIAL OUTLINE :
1. Process Safety Standard
- Convenes and ILO Recommendation
- Hazards Analysis Potency
- Hazard Identification
- Safety Life Cycle
- Safety Integrated Level – SIL Matrix
- Safety Instrumented System – SIS
- Markov Model
- Sample Calculation
2. Failures & Reliability
- Failures
- MTTR
- MTBF
- Fault Tree Analysis
- FMEA
3. Emergency Shutdown System
- Basic Ideas about SIS
- BPCS and SIS
- Emergency Shutdown Systems
- Typical architecture
4. Selecting Sensor for SIS
- Requirements for Sensors used in SIS
- Sensor Selected Based upon Prior Use
- Sensor Capabilities and Limitation
5. SSDS AND DAS SYSTEMS
- Safety Shutdown System Overview
- Data Acquisition System Overview
6. PLC hardware and ladder logic
- Field device connections,
- Wiring/cabling/fusing schemes for various I/O module configurations,
- Review of programming terminal use
7. Configuration of the data files and ladder logic files in the SSDS
8. SIS in practice
- Components of the Safety Loop
- Types of logic Solvers
- Safety Relays-Electromechanical
- Programmable Logic Solvers
- Safety PLCs & General Purpose PLCs
9. Hazardous Area & Electrical Classification
- Hazardous Area Classification
- Electrical Hazard
- Electrical Grounding and Bonding
- Lightning Protection
WHO SHOULD ATTEND?
Technician, operator, supervisor who work in production and want to know comprehensively on electronic safety Shutdown System.
TRAINING DURATION :
4 days
INVESTATION PRICE/ PERSON :
- Rp 6.950.000/person (full fare) or
- Rp 6.750.000/person (early bird, payment 1 week before training) or
- Rp 6.500.000/person (if there are 3 persons or more from the same company)
FASILITAS UNTUK PESERTA :
- Training Module
- Training CD contains training material
- Certificate
- Stationeries: NoteBook and Ballpoint
- Jacket or waistcoat or T-Shirt
- Bag or backpackers
- Training Photo
- Training room with full AC facilities and multimedia
- Once lunch and twice coffeebreak every day of training
- Qualified instructor
- Transportation for participants from hotel of participants to/from hotel of training (if minimal number of participants from one company is 4 persons)
RECOMMENDATION FOR PARTICIPANTS :
For practice session: every participant is recommended to bring laptop/notebook for software installation and practice
TRAINING INSTRUCTOR
Ir. Hasan Surya, MT. is graduated from Bandung Institute of Technology (ITB) for Bachelor and Master program at Electrical Engineering department. Since 1985 till now Ir. Hasan Surya is lecturer at electrical engineering Polytechnique ITB (POLBAN) and he is a head of department at electrical engineering. Ir. Hasan Surya have delivered some training topics related to his major expertise for many companies in Indonesia. Ir. Hasan Surya have been researching in electrical engineering and becoming speaker for some conference. Ir. Hasan Surya has also worked for some companies or institution so he has got much real experiences and now he is ready to share his knowledge and experiences to industrial world throught training class.
cforms contact form by delicious:days
Di akses dari kata kunci : Hasan SuryaEvent lainnya :
- Electrical Protection System Electrical Protection System Tanggal 27-29 Februari 2012 28-30 Mei 2012...
- Distribution System Protection Distribution System Protection Tanggal 23-27 April 2012 10-14 September 2012...
- Electrical Power System Analysis Using Etap Electrical Power System Analysis Using Etap Tanggal 13-16 Februari 2012...
- Grounding System And Lighting Protection Grounding System And Lighting Protection Tanggal 30 April – 03...
- Electronic Filling System Management Electronic Filling System Management Tanggal 6-9 Februari 2012 7-10 Mei...
- Integrated Document & Electronic Filing System Integrated Document & Electronic Filing System Tanggal 23–24 April 2012...
- Training Programmable Logic Controller & Trouble Shooting Training Programmable Logic Controller & Trouble Shooting April 26-29, 2011...
TAG
Components of the Safety Loop, Data Acquisition System Overview, ELECTRONIC SHUTDOWN AND LOGIC SYSTEM, Failures & Reliability, Hazard Identification, Hazards Analysis Potency, Markov Model, MTTR, Safety Shutdown System Overview, SSDS AND DAS SYSTEMS
Navigasi Jadwal
Diposting tgl : August 6th, 2010 | Sudah dibaca 850 kali.